Description
The BEP-M510T Portable Multi-parameter Analyzer adopts a multi-purpose measurement method, which is suitable for the fields of health disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and institutions of higher learning.
General Features
pH
Ion
Conductivity
DO
Specifications
Model |
BEP-M510T |
|
Parameters |
pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) |
|
pH |
Range |
-2.000 to 20.000 pH |
Resolution |
0.1, 0.01, 0.001pH |
|
Accuracy |
±0.002 pH |
|
Calibration Points |
Up to 8 |
|
Standard Customization |
Yes |
|
Calibration Reminder |
Yes |
|
Standard Recognition |
USA, NIST, MERK, JIS, GB and DIN buffers |
|
Slope Limit |
Yes |
|
mV/ORP |
Range |
-2000.00 to 2000.00 mV |
Resolution |
0.1, 0.01 mV |
|
Accuracy |
±0.1 mV or ±0.03% |
|
EH ORP Mode |
Yes |
|
ORP Calibration Points |
1 custom point (relative mV) |
|
pX |
Range |
-2.000 to 20.000 pX |
Resolution |
0.1, 0.01, 0.001 pX |
|
Accuracy |
±0.002 pX |
|
Calibration Points |
Up to 6 |
|
ISE |
Range |
1E-9 to 9.999E9 |
Units |
mol/L, mmol/L, g/L, mg/L, μg/L |
|
Resolution |
Up to 4 significant digits |
|
Accuracy |
±0.3% |
|
Calibration Points |
Up to 8 |
|
Conductivity |
Range |
0.000 μS/cm to 3000 mS/cm |
Resolution |
0.001 μS/cm minimum, |
|
Accuracy |
±0.5% FS |
|
Reference Temperature |
5, 10, 15, 18, 20, 25 ºC |
|
Calibration Points |
Up to 5 |
|
Calibration Reminder |
Yes |
|
Standard Recognition |
10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm |
|
Resistivity |
Range |
5.00 Ω·cm~100.00 MΩ·cm |
Resolution |
0.01 Ω·cm minimum |
|
Accuracy |
±0.5% FS |
|
TDS |
Range |
0.000ppm~1000ppt |
Resolution |
0.001ppm minimum, changed with range |
|
Accuracy |
±0.5%FS |
|
Salinity |
Range |
0.0~80.0ppt |
Resolution |
0.1ppt |
|
Accuracy |
±1ppt |
|
Dissolved |
Sensor Type |
Polarographic |
Range |
0.00 to 99.99 ppm |
|
Resolution |
0.01ppm |
|
Accuracy |
±0.1ppm (0.00 to 50.00 ppm);±0.5ppm(50.00 to 99.99 ppm) |
|
Calibration Reminder |
Yes |
|
Calibration Points |
Air-saturated water or zero point |
|
Barometric Compensation |
Yes |
|
Manual Salinity Factor Correction |
Yes |
|
Saturation |
Range |
(0.0 to 600.0)% |
Resolution |
0.10% |
|
Accuracy |
±10.0% |
|
Temperature |
Range |
-10 to 135 ºC, 14 to 275 ºF |
Unit |
ºC, ºF |
|
Resolution |
0.1 |
|
Relative Accuracy |
±0.1 |
|
Measurement |
Reading Mode |
Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts |
Reading, Stable, Locked |
|
Temp. Compensation |
ATC, MTC |
|
Data management |
Data Storage |
1000 Groups |
GLP Features |
Yes |
|
Inputs |
pH Electrode |
BNC(Q9) |
DO with Temp. Probe |
4-pin aviation connector |
|
Conductivity with Temp. Probe |
5-pin aviation connector |
|
Outputs |
USB |
USB 2.0 flash memory device, PC, scanner |
Display options |
Backlight |
Yes |
Auto Shutdown |
300, 600, 1200, 1800, 3600 sec., off |
|
IP Rating |
IP65 |
|
Date and Time |
Yes |
|
General |
Electricity |
Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions |
90×255×40 mm |
|
Weight |
500g |